V-1
General Description
The Variable Timing Parameters feature gives the PBX the versatility to change timing parameters, using the
MAINTENANCE ADMINISTRATION TERMINAL (MAT) [M-18]. All timing parameters for a specific timing
sequence are set initially within the generic program. These timing parameters can be changed to accommodate user
requirements.
Operating Procedure
No manual operations required. Refer to the NEAX2400 IPX Office Data Specification.
General Description
The following list describes the major VARIABLE TIMING PARAMETERS
1.
Automatic Recall Timer: AUTOMATIC RECALL [A-8]:
a.) standard timing: 30 seconds
b.) variable timing: 2-30 seconds (two-second increments)
2.
No Answer Timer for station call: CALL FORWARDING-DON'T ANSWER [C-3]:
a.) standard timing: 30 seconds
b.) variable timing: 2-30 seconds (two-second increments)
3.
No Answer Timer for station call via an Attendant Console: CALL FORWARDING-DON'T ANSWER
[C-3]:
a.) standard timing: 10 seconds
b.) variable timing: 2-30 seconds (two-second increments)
4.
No Answer Timer for Call Transfer: CALL TRANSFER-ALL CALLS [C-11]:
a.) standard timing: 30 seconds
b.) variable timing: 2-30 seconds (two-second increments)
5.
Periodic Time Indication Tone Timer: PERIODIC TIME INDICATION TONE [P-11]:
a.) standard timing: first period - 3 minutes; other periods - 3 minutes
b.) variable timing: first period - 0.5 to 12.5 minutes (0.5-minute increments), other periods - 0.5 to
12.5 minutes (0.5-minute increments)
6.
Recall Timer for unanswered paging: PAGING TRANSFER [P-10] and RADIO PAGING [R-16]:
a.) standard timing: 30 seconds
b.) variable timing: 30 to 480 seconds (30-second increments).
All other timers are variable (e.g., Register pre-pause timer, Sender pre-pause timer, and switch hook
timer).
If no data is entered, the system operates properly using default data (RAM data). ASYD indexes are not
Note:
usually reprogrammed, with the possible exception of System Data 1, Indexes 156 and 157. All the