NEC NEAX2400 IPX Programming Manual page 827

Feature programming manual
Hide thumbs Also See for NEAX2400 IPX:
Table of Contents

Advertisement

U-1
Programming (cont'd)
STEP 7:
ADSL - Assign UCDBO key; Assign SN=0 (Idle), 3 (Called Station Busy) and FKY = 19 (UCD Busy
Out).
This command is used for assigning a function to each soft key.
STEP 8:
ATRF - Assign Traffic Measurement Order.
TYPE:
INTERVAL: Output Interval must be assigned in units of ten minutes (range is from 30-120 minutes),
FROM-TO-: Measurement time is to be designated.
TIME:
TYPE:
STEP 9:
DTF3 - Display of Traffic Data 3
TYPE:
STEP 10: AUCD/AUCDL - Assign the related data for the UCD group, if necessary. Assign the tenant number/
user group number and the station number/telephone number of the UCD controlling station, QTH
ACT, QTH for the UCD PEG COUNT, CWT for CALL WAITING LAMP UCD [C-76], and MCI for
MESSAGE CENTER INTERFACE [M-26].
STEP 11: APHN - Assign Phantom Number to each UCD controlling station (if necessary).
TN:
REAL STN: Station number of the controlling station
PH:
PHSTN:
Page 784
Uniform Call Distribution (UCD)
Type of Traffic Measurement
or data "0" must be assigned, which is the instruction for assigning output time.
Output Time
1-11
1:
Terminal Traffic Measurement
2:
Route Traffic Measurement
3:
Station Peg Count
4:
Attendant Console Peg Count
5:
Route Peg Count
6:
Service Peg Count
8:
UCD Route Peg Count
9:
UCD Group Peg Count
10:
UCD Station Peg Count
11:
CCIS Traffic Count
Type of Traffic Measurement
8:
UCD Route Peg Count
9:
UCD Group Peg Count
10:
UCD Station Peg Count
Tenant number
Phantom number mode
0 = Used individually
1 = Used as the UCD group number (UCD hunting to be activated)
Phantom station number
NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1

Advertisement

Table of Contents
loading

Table of Contents