S-27
Service Conditions (cont'd)
17.
SPEED CALLING ACCESS-GROUP [S-23] count: Number of times a variable abbreviated number is
registered by stations for which the feature is allowed.
18.
TRUNK ANSWER FROM ANY STATION (TAS) [T-8] count: Number of times the TAS Answer code
is dialed by stations for which the feature is allowed.
19.
OFF-HOOK QUEUING [O-7] count: Number of times an extension accesses an outgoing trunk via OFF-
HOOK QUEUING after initially encountering a condition where all outgoing trunks are busy. The
extension must actually access a trunk in order for the count to be incremented.
20.
ON-HOOK OUTGOING QUEUING-ENTRY [O-2] count: Number of times an extension accesses the
ON-HOOK OUTGOING QUEUING feature by dialing access or going on-hook (if automatic queuing is
provided) after initially encountering a condition where all outgoing trunks are busy. The count will be
incremented each time the feature is accessed, even if the queuing request is cancelled before a trunk is
accessed.
21.
ON-HOOK OUTGOING QUEUING [O-2] cancel count: Number of times ON-HOOK QUEUING is
cancelled by dialing the cancel code.
22.
CONSULTATION HOLD-ALL CALLS [C-17] count: Number of times CONSULTATION HOLD is
executed.
23.
CALL TRANSFER-ALL CALLS [C-11] count: Number of times a call is transferred to another extension
before the called party answers, without Attendant involvement. A call originated internally or from the
outside will be registered in the count.
24.
THREE-WAY CALLING [T-2] count: Number of times THREE-WAY CALLING occurs without
Attendant assistance.
25.
The maximum Tenant Number Counting SERVICE FEATURE PEG COUNT is 63 tenants.
Note:
Additional hardware is required.
Programming
STEP 1:
ASYD - System Data 1, Index 47, Bit 7. Are traffic measurements required? 0/1: No/Yes.
Refer to the following commands to order PEG COUNTS
STEP 2:
ATRF - Assignment of Traffic Measurement Order (CM03)
TYPE:
PORT:
INTERVAL: Output Interval must be assigned in units of 10 minutes (range of between 30-120
FROM-TO-: Measurement is to be designated.
TIME:
TYPE:
1: Terminal Traffic Measurement
2: Route Traffic Measurement
3: Station Peg Count
4: Attendant Console Peg Count
5: Route Peg Count
6: Service Peg Count
8: UCD Route Peg Count
9: UCD Group Peg Count
Page 706
Service Feature Peg Count
Type of Traffic Measurement
Port number where Traffic Data is to be output.
minutes), or data "0" must be assigned, which is the instruction for assigning output
time.
Output Time
NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1