NEC NEAX2400 IPX Programming Manual page 303

Feature programming manual
Hide thumbs Also See for NEAX2400 IPX:
Table of Contents

Advertisement

C-157
Service Conditions (cont'd)
18.
The trunk mentioned below is available as for analog COT:
19.
When this feature is activated via FCCS, the same data should be set to all nodes.
Programming
STEP 1:
ASYD - System Data 1, Index 241, b6: Assign the data when the length of Caller ID exceeds the limit:
0/1 = Only the former/latter part of data appears on the LCD.
Index 390,
b0:
Assign the prior data to display
0/1:
The Assigned Name/The Calling Number
b1:
Assign the information displayed on the top line of the LCD
0/1:
0=Caller ID data
1=Call Type, Sub-address
b2:
Enable to display Caller ID information on the D
sub line.
0/1:
Out/In service
STEP 2:
ACID - Assign the desired name against the calling number.
TYPE 3: Calling Party Number - Name Assignment and Display
CID:
Caller ID Number
SRV3:1 Calling Party Number - Name Assignment and Display
NAME: 24 digits maximum
STEP 3:
AKYD - Assign the Call ID display change key to a feature key. FKY = 113
STEP 4:
ADSL - Assign the Call ID display change key to a soft key.
SN = 0, 3
FKY = 113
FCCS Programming
No unique programming is required for the FCCS network.
Page 260
Calling Party Number - Name Assignment and Display
CIRCUIT CARD NAME
PA-8COTBJ
REMARKS
term
to which the called line is assigned as a
NEAX2400 IPX Feature Programming Manual