R-7
Programming
STEP 1:
Initialization of the system will automatically provide for Maintenance Administration Terminal
capabilities in System Data 1, Index 116 for Port 0.
STEP 2:
AIOC - Assign the function and attribute data of each I/O port to be used.
STEP 3:
Assign Terminal Configuration data (Serial Settings/TCPIP Settings) in the PBX Administration
menu.
STEP 4:
AUIDN - This command must be assigned to allow password protection. Assign the following:
TYPE:
Data Type
1-Password Code Data
2-Grade 2 Command Data
GRD-1: Grade 1 Password
CDN:
1-15, against the Grade 1 Password, 15 Grade 2 Passwords may be assigned.
GRD-2: Assign the Grade 2 Passwords.
TYPE:
2-Grade 2 Command Data.
CDN:
1-16, Against each Grade 2 Passwords allow access to 16 commands.
CMND: List the 16 commands.
FCCS Programming
No unique programming is required for the FCCS network.
Page 624
Remote Maintenance
NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1