NEC NEAX2400 IPX Programming Manual page 688

Feature programming manual
Hide thumbs Also See for NEAX2400 IPX:
Table of Contents

Advertisement

Programming
STEP 1:
ASYD - System Data 2, Index 1, bit 7. Does TOLL RESTRICTION [T-7] apply to SPEED
CALLING-SYSTEM? 0/1: No/Yes.
STEP 2:
ANPD - Reserve a number level for feature access. Assign Connection Indexes of Normal (N),
Hooking (H), and Busy (B). Assign NND in accordance with a predetermined numbering plan.
STEP 3:
ASPA - Assigning an access code to SPEED CALLING-SYSTEM, assign SRV = SSC (Service
Code), SID = 15. Program for Normal (N). NND = Access code plus Abbreviated Digit Code (ADC).
See ASPD.
Example: 6 + 010 1 digit + 3 digits = NND = 4.
STEP 4:
ASFC - Assign a Service Feature Class that allows SFI 12 to stations that will have SPEED
CALLING-SYSTEM.
STEP 5:
ASPD - Assign the Tenant Number, ADC, and CD-telephone number to be sent. Include the access
code of the route in the CD.
STEP 6:
AKYD - Assign SPEED CALLING to D
STEP 7:
ADSL - Assign S-SPD key; Assign SN=1 (Originating; DT Connection) and FKY=15 (Speed Calling
- System).
This command is used for assigning a function to each soft key.
FCCS Programming
This data setting describes only the additional or replacement commands used to activate FCCS
services. When used as an FCCS feature, these commands replace the non-network commands (for
example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending
on the node.
STEP 1:
ANPDL - Reserve a number level for feature access. Assign Connection Indexes of Normal (N),
Hooking (H), and Busy (B). Assign NND in accordance with a predetermined numbering plan.
STEP 2:
ASPAL - Assigning an access code to SPEED CALLING-SYSTEM, assign SRV = SSC (Service
Code), SID = 15. Program for Normal (N). NND = Access code plus Abbreviated Digit Code (ADC).
See ASPD.
Example: 6 + 010 1 digit + 3 digits = NND = 4.
Note:
When using ASYDL or ASYDN to program an FCCS feature, the basic programming of ASYD is required
in addition to ASYDL or ASYDN.
NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Speed Calling - System - D
Note
term
term
key. Assign FKY15 to the D
S-3D
term
key.
Page 645