M-30
Interactions (cont'd)
4.
When an incoming call is answered by the sub-line appearance on another station, the following services
may be activated either by the answering station or by another station towards the answering station. These
services will not interfere with the answering station's ability to leave a Message Waiting indication.
PRIVACY-D
CONSULTATION HOLD-ALL CALLS
ATTENDANT CAMP-ON WITH TONE INDICATION (set to answering station)[A-1]
CALL WAITING-ORIGINATING (set to answering station)
CALL WAITING-ORIGINATING (set from answering station) [C-31]
THREE-WAY CALLING-D
NON-EXCLUSIVE HOLD-D
EXCLUSIVE HOLD-D
DUAL HOLD
5.
Message Waiting can be set to yourself if you wish to leave yourself a reminder.
6.
Numbering plan data (ANPD and ASPA) is not required if only digital D
Programming
STEP 1:
ANPD - Reserve a number level for feature access and cancel. Assign Connection Indexes, CI = N, H,
B; Normal (N), Hooking (H), and Busy (B) (applicable to any feature assigned to this level). Assign
NND in accordance with a predetermined numbering plan.
STEP 2:
ASPA - Assign an access code for setting the Message Waiting Lamp. Set SRV = SSCA (Service
Code Appendix); SIDA = 54. Cancel Message Waiting Lamp SRV = SSCA (Service Code Appendix);
SIDA = 55. Assign Connection Status Index (CI) for Normal (N) service.
STEP 3:
ASFC - Assign a Service Feature Class that allows SFI = 74 and SFI = 82 to the stations that receive
the Message Waiting Lamp setting feature.
STEP 4:
AKYD - Assign Message Waiting Lamp set feature to a programmable line/feature key. Assign
Type:Function:BOSS-SECRETARY MSG WAIT-SET [9] and a Message Waiting Lamp cancel key,
Type:Function:BOSS-SECRETARY MSG WAIT-CANCEL [11].
Assign SN=1 (Originating; DT Connection) and FKY=11 (Boss - Secretary - Message Waiting Lamp
Control; Cancel).
STEP 5:
ADSL - Assign SN=1, 2, 3, 4, 5 and FKY=9 (Boss-Secretary-Message Waiting Lamp Control; Set).
Assign SN=1, 2, 3, 4, 5 and FKY=11 (Boss-Secretary-Message Waiting Lamp Control; Cancel).
This command is used for assigning the function to each soft key.
FCCS Programming
This data setting describes only the additional or replacement commands used to activate FCCS
services. When used as an FCCS feature, these commands replace the non-network commands (for
example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending
on the node.
STEP 1:
ANPDL - Reserve a number level for feature access and cancel. Assign Connection Indexes, CI = N,
H, B; Normal (N), Hooking (H), and Busy (B) (applicable to any feature assigned to this level). Assign
NND in accordance with a predetermined numbering plan.
STEP 2:
ASPAL - Assign an access code for setting the Message Waiting Lamp. Set SRV = SSCA (Service
Code Appendix); SIDA = 54. Cancel Message Waiting Lamp SRV = SSCA (Service Code Appendix);
SIDA = 55. Assign Connection Status Index (CI) for Normal (N) service.
Page 514
Message Waiting Lamp Setting - Station
term
term
term
term
[P-14D]
[C-17]
[C-31]
[T-2D]
[N-7D]
[E-4D]
[D-32]
term