Programming
STEP 1:
ASYD - System 1, Index 32, Bit 0: At the time of SMDR processor trouble, outgoing call is not
restricted/restricted = 0/1. Bit 1: Tenant information is recorded (1). Bit 2: Route information is
recorded (1). Bit 7: SMDR services are provided (1).
System 1, Index 33, Bits 3 & 4: Designation of a total of parties to be billed. Bit 5: Designation of
billing system for a transferred incoming call. Bit 6: Designation of billing system for a transferred
outgoing call.
System 1, Index 34, Bit 0: RS-232C non-procedure output function is provided. Bits 1 & 2:
Designation of RS-232C Output Code. Bit 3: Designation of the number of RS-232C Stop Bits.
System 1, Index 95, Bits 0-6: SMDR RS-232C Variable Timer setting for the case where computer
output cannot be provided. Billing data are stored until this timer times out. Bit 7: Valid/Invalid
Variable Timer (0/1).
System 1, Index 180/181: Assignment of the Self Office Point Code (OPC).
System 1, Index 182/183: Assignment of the Center Office Point Code (DPC) (when the self office is
the Center Office, DPC = 0).
System 1, Index 288: Designation of RS-232C non-procedure output port (SMDR).
System 2, Index 3, Bit 0: SMDR Service (1). Bit 7: SMDR Station-to-Station Connection Data (1).
STEP 2:
ASFC - With respect to SFC of the billing subject stations, clear the restriction of SFI = 14 (SMDR -
Trunk Basis) and, if necessary, SFI = 58 (SMDR STN to STN).
STEP 3:
ARTD - With respect to the Route Class of Outgoing and Incoming Trunks, assign SMDR = 1,
SMDR3 = 0. The parameters for SMDR2 are pertaining to incoming call billing processing service.
Assign data to the parameters on an as required basis.
STEP 4:
AMND - Assign necessary maximum number of digits for the number to be dialed on origination of an
outgoing call. As many digits as assigned are given out as the Called No. of SMDR information.
STEP 5:
AIOC - Assign Baud Rate, Parity Bit, Stop Bit etc. of the designated Output Port for SMDR. (See
STATION MESSAGE DETAIL RECORDING (SMDR) [S-10].)
FCCS Programming
The method for this service can be selected whether Centralized Billing - CCIS (CCIS method) or
Centralized Billing - FCCS (FCCS method). For FCCS method, see STATION MESSAGE DETAIL
RECORDING (SMDR) [S-10].
STEP 1:
Set the data for the Centralized MAT following programming of CENTRALIZED MAINTENANCE -
CCIS
[C-167]
CCIS [N-46].
NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Centralized Billing - CCIS
and telephone number (maximum of 8 digits) following NUMBER PORTABILITY -