Errdisable Recovery - D-Link DGS-6600-48T Cli Reference Manual

Modular layer 3 chassis ethernet managed switch
Hide thumbs Also See for DGS-6600-48T:
Table of Contents

Advertisement

DGS-6604
m

errdisable recovery

errdisable recovery cause {all | loopback-detection } [ intervalSECONDS ]
no errdisable recovery cause {all | loopback-detection } [ interval ]
Syntax Description
all
loopback-detection
intervalSECONDS
Default
Command Mode
Usage Guideline
Example
Switch# configure terminal
Switch(config)# errdisable recovery cause loopback-detection interval 200
Switch(config)# end
CLI Reference Guide
Use the errdisable recovery command to enable and configure the error
recovery function. Use the no command to disable the auto recovery for causes
or to return interval to default setting for causes.
Specifies the configure auto recovery for all causes.
Specifies the configure auto recovery of error report caused by loopback-
detection
Specifies the time, in seconds, to recover the port from an error state caused by
the specified module. The valid value is 30 to 86400.
Auto recovery is disabled for all causes
If enabled, the Interval is 300 seconds
Global configuration
A port can be put in error disabled state (an operational state that is similar to the
link-down state) by causes such as loopback detection.
A port in error disabled state can not transmit nor receive any packets.
An error disabled port can be either manual recovered or automatically restored
by using this command.
The user can enter shutdown and then no shutdown commands to recover an
interface manually from the error-disabled state.
If auto recovery is enabled for a specific cause, the port error disabled by that
caused will be auto recovered once the cause have timed out.
This example shows how to set the recovery timer to 200 seconds for port
loopback-detection.
errdisable recovery