Show Ipv6 Interface - D-Link DGS-6600-48T Cli Reference Manual

Modular layer 3 chassis ethernet managed switch
Hide thumbs Also See for DGS-6600-48T:
Table of Contents

Advertisement

DGS-6604
m

show ipv6 interface

show ipv6 interface [IFNAME]
Syntax
Default
Command Mode
Usage Guideline
Example
Switch > enable
Switch # show ipv6 interface vlan1
vlan1 is down,
IPv6 is disable
link-local address is :
fe80::a01:2ff:fe39:1
global unicast address is :
3ffe:501:ffff:100:a01:2ff:fe39:1/64 (DAD check fail)
MAC Address is 08-01-02-39-00-01
IP MTU is 1500 bytes
IPv6 Hop Limit is 64
ICMP error messages limited to one every 100 milliseconds
ICMP redirects are enabled
ND DAD is enabled, number of DAD attempts: 1
ND reachable time is 30000 milliseconds
ND advertised is sending
ND advertised reachable time is 604151836 milliseconds
ND advertised retransmit interval is 257243264 milliseconds
ND router advertisements are sent between 604143192 to 5 seconds
ND router advertisements live for 54212 seconds
Hosts use stateless autoconfig for addresses.
Switch #
CLI Reference Guide
These commands are used to display IPv6 interface information.
None
None
EXEC mode or any configuration mode.
If the IPv6 address DAD fail, the IPv6 address is marked "DAD check fail"
This example shows how to display IPv6 interface incidence: