DGS-6604
m
switch# show poe power inline status
Interface Priority PSE State
Range
===========================================================================
====
3.1
1st
3.2
1st
...
4.1
1st
4.2*
1st
4.3
2nd
4.4
2nd
...
switch# show poe power inline statistic
Interface MPS-Absent Overload Short Power-Denied Invalid-Signature
--------- ---------- -------- ----- ------------ -----------------
3.1
2
3.2
2
...
4.1
2
4.2
2
4.3
2
4.4
2
...
CLI Reference Guide
on
delivering
on
delivering
on
delivering
on
delivering
off searching
off searching
This is an example of output from the show poe power-inline statistic command.
5
0
1
0
0
0
0
0
0
0
0
0
This is an example of output from the show poe power-inline measurement
command.
OP Mode Class
auto
class-1
auto
class-2
static
class-3
auto
class-3
never
class-0
static
class-0
10
0
3
0
2
0
1
0
5
0
0
0
show poe power-inline
Max(mW) Used(W) Time-
4000
3.5
7000
6.7
15400
15.0
15400
12.4
15400
0
11000
0
--
rdtime
--
--
daytime
--
817