Logging Level - D-Link DGS-6600-48T Cli Reference Manual

Modular layer 3 chassis ethernet managed switch
Hide thumbs Also See for DGS-6600-48T:
Table of Contents

Advertisement

DGS-6604
m

logging level

logging level all SEVERITY
Syntax Description
all
SEVERITY
Severity Level
0
1
2
3
4
5
6
7
Default
Command Mode
Usage Guideline
Example
switch> enable
switch# configure terminal
Switch(config)# logging level all 1
CLI Reference Guide
Use this command to limit messages logged to the message buffer based on
severity level.
All facilities
Value for the severity level of system messages to capture. Severity level
definitions are shown in the following table.
Severity Type
emergency
alert
critical
error
warning
notice
informational
debugging
SEVERITY: 5
Global configuration
The command limits the logging of system messages to the syslog buffer to only
those messages for the specified facility at and up to the specified severity level.
For example, if the buffer severity is 7 (debugging) then all logs in syslog daemon
will log to buffer. If buffer severity is 1 (alert), then only alert and emergency logs
will be logged to buffer.
The below example limits logs with severity alert and emergency to be logged to
buffer for all facilities.
Verify the settings by entering the show logging command.
Description
system is unusable
action must be taken
immediately
critical conditions
error conditions
warning conditions
normal but significant
condition
informational messages
debugging messages
logging level