Sflow Sampler - D-Link DGS-6600-48T Cli Reference Manual

Modular layer 3 chassis ethernet managed switch
Hide thumbs Also See for DGS-6600-48T:
Table of Contents

Advertisement

DGS-6604
m

sflow sampler

sflow sampler INSTANCE [receiver RECEIVER][sampling-rate RATE][max-header-size SIZE]
no sflow sampler [INSTANCE]
Syntax
INSTANCE
receiver RECEIVER
sampling-rate RATE
max-header-size SIZE
Default
Command Mode
Usage Guideline
CLI Reference Guide
Use the sflow sampler command to create/configure a Sampler for the sFlow
agent. Use the no form of this command to delete one Sampler or all Samplers.
The instance index if multiple Samplers are associated with one interface. The
valid range is from 1 to 65535.
The Receiver's INDEX for this Sampler. If not specified, the value is 0.
(Optional)
The user can not configure the value to 0. The maximum number is project
dependent.
The rate for packet sampling. The range is from 0 to 65536. 0 means
(Optional)
disable. If not specified, the default value is 0.
The maximum number of bytes that should be copied from sampled
(Optional)
packets. The range is from 18 to 256. If not specified, the default value is 128.
No Sampler is created.
Interface configuration mode
The command is available for physical port interface configuration.
A sampler can only be configured on one interface. It cannot be associated with
multiple interfaces.
Use this command without keywords to create a default Sampler or to reset an
existing Sampler to default values. Use the no form of this command with
INSTANCE to delete one Sampler. Use the no form of this command without
INSTANCE to delete all Samplers.
The user can only specify a Receiver that has its owner name setup. If the
Receiver associated with the sampler has its owner name reset, the sampler will
be reset to the default setting. The Receiver ID of a default sampler is 0.
Set sampling rate to N will cause the system to sample one packet for every N
packets arriving on the monitored interface. The sampled packet is sent to the
sFlow Receiver. Setting the sampling rate to 0 will disable the sampling. The
granularity of the sampling rate is project dependent.
An interface can be configured with multiple samplers. If multiple samplers are
configured, the configured sampling rate can be different. However, the sampling
rate of all other samplers must be multiples in power of 2 of the minimal sampling
rate.