Subnet-Base ( Vlan) - D-Link DGS-6600-48T Cli Reference Manual

Modular layer 3 chassis ethernet managed switch
Hide thumbs Also See for DGS-6600-48T:
Table of Contents

Advertisement

DGS-6604
m
subnet-base ( VLAN )
subnet-base { NETWORK-PREFIX NETWORK-MASK | NETWORK-PREFIX / PREFIX-LENGTH }
no subnet-base { NETWORK-PREFIX NETWORK-MASK | NETWORK-PREFIX / PREFIX-LENGTH }
Syntax Description
NETWORK-PREFIX
NETWORK-MASK
NETWORK-PREFIX/
PREFIX-LENGTH
Default
Command Mode
Usage Guideline
Example
Switch(config)#vlan 100
Switch(config-vlan)#subnet-base 20.0.1.0/8
Switch(config-vlan)#subnet-base 192.0.1.0/8
Switch(config-vlan)#end
CLI Reference Guide
Use the subnet command to specify a subnet-based VLAN ID assignment for un-
tagged incoming packets. Use the no form of this command to remove a subnet-
based VLAN ID entry setting.
The network prefix and the network mask specify the destination network in the
form of A.B.C.D xxx.xxx.xxx.xxx.
The network prefix and the prefix length specify the destination network in the
form of A.B.C.D/x.
Not configured
VLAN configuration
A subnet VLAN entry is an IP subnet-based VLAN classification rule. If an
untagged or priority-tagged IP packet is received on a port, its source IP address
will be used to match the subnet VLAN entries. If the source IP matches the
subnet of an entry, the packet will be classified to the VLAN of this entry. The
number of subnet-based VLAN entries is project dependent.
This example shows how to create a subnet-based VLAN entry.
Verify the settings by entering the show vlan command.
subnet-base ( VLAN )