3HAC020993-001 Revision: Z
Action
Reconnect connectors to the SMB unit:
R2.SMB
R1.SMB1-3
R1.SMB4-6
Reconnect connectors to the Brake release
unit:
X8
X9
X10
Reconnect R1.G if it has been disconnected.
Secure the SMB cover with its attachment
screws.
If cabling is used for 7th axis (option), refit the
connector R2.FB7 to the SMB cover and
tighten with 6 Nm.
WARNING
Before continuing any service work, please
observe the safety information in section
brake release buttons may be jammed after
service work on page
218!
Push the cable harness gently through the
lower arm.
Refit the cable gland securing the cables inside
the lower arm.
© Copyright 2004-2018 ABB. All rights reserved.
4.3.1 Replacing cable harness, axes 1-6