ABB IRB 6650S Series Product Manual page 400

Table of Contents

Advertisement

5 Calibration
5.3 Updating revolution counters
Continued
4
5
6
7
8
400
Action
A screen is displayed, tap Rev. Counters.
en0400000771
Tap Update Revolution Counters....
A dialog box is displayed, warning that updating the revolution counters may change
programmed robot positions:
Tap Yes to update the revolution counters.
Tap No to cancel updating the revolution counters.
Tapping Yes displays the axis selection window.
Select the axis to have its revolution counter updated by:
Ticking in the box to the left
Tapping Select all to update all axes.
Then tap Update.
A dialog box is displayed, warning that the updating operation cannot be undone:
Tap Update to proceed with updating the revolution counters.
Tap Cancel to cancel updating the revolution counters.
Tapping Update updates the selected revolution counters and removes the tick from
the list of axes.
CAUTION
If a revolution counter is incorrectly updated, it will cause incorrect manipulator posi-
tioning, which in turn may cause damage or injury!
Check the synchronization position very carefully after each update. See
the synchronization position on page
© Copyright 2004-2018 ABB. All rights reserved.
414.
Product manual - IRB 6650S
3HAC020993-001 Revision: Z
Checking

Advertisement

Table of Contents
loading

Table of Contents