Defaults
None
Command Modes
EXEC Privilege
Command History
Version
9.9 (0.0)
9.2(1.0)
8.3.19.0
8.3.11.1
8.4.1.0
Usage Information Use the show util-threshold memory command to display the memory utilization
thresholds used to send SNMP traps. When switch CPUs exceed the configured (high or
low) memory percentage to process packets or data, a threshold notification is sent as
an SNMP trap. To reconfigure the currently configured values, use the util-
threshold memory command.
Example
Dell#show util-threshold memory
Processor
================================
CP
RP
LP 0
LP 1
LP 2
LP 3
LP 4
LP 5
LP 6
LP 7
LP 8
LP 9
LP 10
LP 11
PE
Related
•
Commands
•
Description
Introduced on the C9010.
Introduced on the Z9500.
Introduced on the S4820T.
Introduced on the Z9000.
Introduced on the C-Series, E-Series, S25 and S50.
High
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
util-threshold mem
– Configure memory utilization thresholds.
util-threshold cpu
– Configure CPU utilization thresholds.
Low
82
82
82
82
82
82
82
82
82
82
82
82
82
82
82
Control and Monitoring