4 Repair
4.3.2. Replacement of cabling, axis 5 motorIRB 6640
Continued
Refitting, cabling axis 5 motor
The procedure below details how to refit the cabling to the motor of axis 5.
206
Action
3. Remove the cover of motor, axis 5.
4. Disconnect all connectors at motor, axis 5.
5. Remove the cable gland cover at the cable
exit by unscrewing its two attachment screws.
6. Remove the cable, axis 5.
Action
1.
DANGER!
Turn off all electric power, hydraulic and
pneumatic pressure supplies to the robot!
For Foundry Prime robots: Do not turn off the
air pressure to motors and SMB.
2. Reconnect all connectors at motor, axis 5.
3. Refit the cable gland cover at the cable exit
with its two attachment screws.
4. Refit the cover of motor, axis 5.
5. Refit the complete wrist unit.
6. Recalibrate the robot.
7.
DANGER!
Make sure all safety requirements are met
when performing the first test run. These are
further detailed in section
test run may cause injury or damage! on page
33.
Note
Note
Detailed in section:
Calibration is detailed in a separate
calibration manual, enclosed with the
calibration tools.
General calibration information is
included in section
mation.
DANGER - First
IRB
6640:Refitting, wrist unit
on page
254.
IRB 6640ID:
Refitting, wrist unit
on page
258.
Calibration infor-
3HAC026876-001 Revision: C