ABB IRB 6640 - 180/2.55 Product Manual page 320

Articulated robot
Table of Contents

Advertisement

4 Repair
4.6.3. Replacement of motor, axis 3
Continued
20.
Replacement of the motor axis 3 (Foundry Prime)
Robots working with Foundry Prime and that have the special tightness for this application
require special repair routines to maintain the tightness level.
The repair must be done according to the previous repair procedures with the following
additions.
318
Action
DANGER!
Make sure all safety requirements are met when
performing the first test run. These are further
detailed in section
DANGER - First test run may
cause injury or damage! on page
Action
1.
DANGER!
Turn off all electric power, hydraulic and
pneumatic pressure supplies to the robot!
For Foundry Prime robots: Do not turn off the air
pressure to motors and SMB.
2. Remove the motor according to step 2 - 4 in
Removal, motor on page
3. Remove the cover for connector access on top of
the motor by unscrewing its four attachment
screws.
Note
33.
Note
314.
xx0600002874
B
A
A: Attachment screw
B: Air hose
C: Top cover
D: Motor unit
Continues on next page
3HAC026876-001 Revision: C
C
D