Installation, separate fan cabling axis 1 or 2
The procedure below details how to install the separate cabling for the cooling fan of axis 1
or 2.
3HAC026876-001 Revision: C
2.5.9. Installation of cooling fan for motors, axes 1 and 2 (option)
Action
1. Move the robot to its calibration position.
2.
DANGER!
Turn off all electric power, hydraulic and pneumatic
pressure supplies to the robot!
For Foundry Prime robots: Do not turn off the air
pressure to motors and SMB.
3. Remove the rear cover plate from the robot base. Shown in the figure
4. Remove the cable bracket (A)
5. Fit the plate for customer connections, if not
already fitted, to the connection plate of the robot
base.
6. Run the cabling up through the base and frame,
beneath the balancing device.
2 Installation and commissioning
Note
Shown in section
scales and correct axis position on
page
376.
cooling fans on page
Shown in the figure
cabling for axis 1 or 2 on page 88
Shown in the figure
customer connections, at base on
page
87.
Art. no. is specified in
equipment on page
Continues on next page
Continued
Calibration
Location of
85.
Separate
Plate for
Required
86.
89