Epson Research and Development
Vancouver Design Center
13706CFG Configuration Program
Issue Date: 01/03/29
Mono / Color
Format 2
FPLINE Polarity
FPFRAME Polarity
Panel Dimensions
Display Total
Display Start
Selects between a monochrome or color panel.
Selects color STN panel format 2. This option is specif-
ically for configuring 8-bit color STN panels.
See the S1D13706 Hardware Functional Specification,
document number X31B-A-001-xx, for description of
format 1 / format 2 data formats. Most new panels use
the format 2 data format.
Selects the polarity of the FPLINE pulse.
Refer to the panel specification for the correct polarity
of the FPLINE pulse.
Selects the polarity of the FPFRAME pulse.
Refer to the panel specification for the correct polarity
of the FPFRAME pulse.
These fields specify the panel width and height. A
number of common widths and height are available in
the selection boxes. If the width/height of your panel is
not listed, enter the actual panel dimensions into the edit
field.
For passive panels, manually entered pixel widths must
be a minimum of 32 pixels and can be increased by
multiples of 16. For TFT panels, manually entered pixel
widths must be a minimum of 16 pixels and can be
increased by multiples of 8. If a value is entered that
does not match these requirements, a notification box
appears and 13706CFG rounds up the value to the next
allowable width.
It is recommended that these automatically generated
Display Total values be used without adjustment.
However, manual adjustment may be useful in fine
tuning the horizontal and vertical display totals.
The display total equals the display period plus the non-
display period.
It is recommended that these automatically generated
Display Start values be used without adjustment.
However, manual adjustment may be useful in fine
tuning the horizontal and vertical display start positions.
For passive panels these values must always be 0.