Digital Part Of Combi I/O And Digital I/O Unit - ABB IRC5 Product Manual

Robot controller
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

1
2
3)
/13.3 / +24V devicenet
/13.3 / 0V devicenet
/33.5 / V-
/33.5 / CAN_L
/33.5 / CAN_H
/33.5 / V+
/33.5 / DRAIN
OR PREVIOUS
I/O UNIT
1) JUMPERS PLACED ACCORDING TO
THE ACTUAL NODE ADDRESS.
2) RESISTANS 120 OHM SHALL ALWAYS
BE CONNECTED IN THE FIRST AND THE
LAST CONNECTOR IN THE CAN-BUS CIRCUIT.
3) CONNECTED IN THE LAST CONNECTOR IN THE
CAN-BUS CIRCUIT.
4) ONLY FOR DIGITAL I/O DSQC 652
Latest revision:
Prepared by, date:
Approved by, date:
JSUNDIN
3
TO NEXT
I/O UNIT
2)
120 ohm
2
1
DIG. PART OF COMBO I/O AND DIG. I/O UNIT DSQC 651& 652
-I/O1
-X5
1 1
2 2
4 4
5 5
0V
3 3
NA0
6 6
NA1
7 7
1)
NA2
8 8
NA3
9 9
NA4
10
10
NA5
11
11
12
12
MTORNROS
4
5
K
1
1
2
A
1
K
A
2
1
0V
K
A
A
A
Lab/Office:
DIGITAL PART OF COMBI I/O AND
DIGITAL I/O UNIT
6
7
XTXX.X3
X3
INPUT CH.1
1030
I/O1 X3:1 / /48.3 /52.2 /52.6
2
1034
I/O1 X3:2 / /48.4 /52.2 /52.6
1 1
3
1035
I/O1 X3:3 / /48.4 /52.2 /52.6
2 2
4
1036
I/O1 X3:4 / /48.4 /52.3 /52.6
3 3
5
1037
I/O1 X3:5 / /48.5 /52.3 /52.7
4 4
6
1028
I/O1 X3:6 / /48.3 /52.1 /52.5
5 5
7
1033
I/O1 X3:7 / /48.4 /52.2 /52.6
6 6
8
1029
I/O1 X3:8 / /48.3 /52.1 /52.5
7 7
0V
1055
8 8
9 9
10
10
4)
XTXX.X4
X4
INPUT CH.9
1044
I/O1 X4:1 / /48.6 /50.6 /52.4 /52.8
10
1031
I/O1 X4:2 / /48.3 /50.4 /52.2 /52.6
1 1
11
1045
I/O1 X4:3 / /48.6 /50.6 /52.4 /52.8
2 2
12
1061
I/O1 X4:4 / /48.6 /50.6 /52.4 /52.8
3 3
13
1062
I/O1 X4:5 / /48.6 /50.6 /52.4 /52.8
4 4
14
5 5
15
1038
I/O1 X4:7 / /48.5 /50.5 /52.3 /52.7
6 6
16
1039
I/O1 X4:8 / /50.5 /48.5 /52.3 /52.7
7 7
0V
1060
8 8
9 9
10
10
Status:
2008-07-17
Approved
Document no.
3HAC024120-004
8
=
Plant:
EUROMAP
+
Location:
CM
+
Sublocation:
Rev. Ind
Page 36
Next
37
03
Total
48