4 Repair activities, controller IRC5
4.20. Replacement of Compact Flash memory in computer unit DSQC639
Continued
Refitting
The procedure below details how to refit the Compact Flash memory in the computer unit.
274
Action
1.
DANGER!
Before any work inside the cabinet, please
observe the safety information in section
DANGER - Make sure that the main power
has been switched off! on page
2.
esd
WARNING!
The unit is sensitive to ESD, before handling
the unit please observe the safety information
in section
WARNING - The unit is sensitive to
ESD! on page 29
3. Refit the Compact Flash memory.
Note/Illustration
28.
xx0600002924
3HAC021313-001 Revision: K