Connecting A Limit Switch Override Push Button; Procedure For Single Cabinet Controller - ABB IRC5 Product Manual

Robot controller
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

2 Installation and Commissioning, IRC5

2.5.15. Connecting a Limit switch override push button

2.5.15. Connecting a Limit switch override push button
DANGER!
The Limit switch override is used to disconnect safety limitations. Make sure the Limit switch
override function is not active longer than absolutely necessary.
If the option SafeMove is implemented, Limit switch override must never be used at all. The
SafeMove safety controller has its own override function.
General
The override circuit enables the possibility to jog an axis out of a forbidden (limited) zone.
Limitations
The switch has to be placed inside the controller to eliminate the risk of electrical noise.
Required equipment
Equipment
Contact block
Contact blocks with holder
Push button (in Dual Cabinet)
Connector X23
Wire
Standard toolkit
Circuit diagram

Procedure for Single Cabinet Controller

The following procedure details how to connect a Limit switch override circuit in a Single
Cabinet Controller.
82
Action
1.
Danger
DANGER!
Before any work inside the IRC5 controller
modules, please observe the safety
information in section
DANGER - Make
sure that the main power has been
switched off! on page
28.
Art. no
1SFA 610 605 R1001
1SFA 611 605 R1201
1SFA 611 102 R1105
1SSA 245 204 R0100
Note/illustration
Note
ABB CW Control
ABB CW Control
ABB CW Control
ABB CW Control
Cable AWG 20 Blue
Described in section,
Standard Toolkit.
See
Circuit Diagram on
page 341
Continues on next page
3HAC021313-001 Revision: K