Connection To Motors On/Motors Off Contactor - ABB IRC5 Product Manual

Robot controller
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

2 Installation and Commissioning, IRC5

2.5.12. Connection to MOTORS ON/MOTORS OFF contactor

2.5.12. Connection to MOTORS ON/MOTORS OFF contactor
General
This section details connection to the MOTORS ON/MOTORS OFF contactor. To be used
when the customer wants external equipment to follow the robot control.
Location
The MOTORS ON/MOTORS OFF contactor is located on the left hand side in the Drive
Module.
xx0400001058
A
B
C
D
E
Required equipment
The table below details the required equipment.
Equipment
Standard toolkit
Circuit Diagram
Technical data
The table below shows technical data.
Technical data
Max. voltage
Max. current
Max. potential in relation to the cabinet earthing
and other signal groups.
Signal class
74
A
B
D
E
MOTOR ON contactor K42 / K43
Contactor auxilary block 33-34
Brake contactor
Jumper (3 pcs)
Contactor interface board
C
Note
See
Circuit Diagram on page 341
48 VDC
4 A
300 V
Control signals
3HAC021313-001 Revision: K
Continues on next page