3HAC021313-001 Revision: K
Action
3. Refit the fan on the fan plate.
Press in the plastic rivets to fasten the fan on
the fan plate.
4. Refit the fan unit in to the computer unit.
Fold the fan plate locking device to fasten the
fan unit to the computer unit.
5. Reconnect the cable to the motherboard.
6. Close the computer unit.
7. Refit the computer unit.
4 Repair activities, controller IRC5
4.18. Replacement of fan in computer unit DSQC639
Note/Illustration
xx0800000207
A: plastic rivet (4 pcs)
xx0800000206
A: fan plate locking device
Detailed in section
motherboard in computer unit
DSQC639 on page
Detailed in section
computer unit DSQC639 on page
Continued
A
A
Replacement of
235.
Replacement of
226.
267