Kenwood NEXEDGE NX-200 Function Reference page 132

Hide thumbs Also See for NEXEDGE NX-200:
Table of Contents

Advertisement

6 SOUND
6.6 Restricting Alert Tone When Consecutively Receiving a Call (Alert Tone Restriction from 2nd Call) (NXDN System only)
 Behavior examples of when the transceiver receives a Group Call
If the transceiver receives a Group Call, various functions such as Alert Tone are not activated when the transceiver
receives a Group Call again using the same Group ID before the time configured for Auto Reset Timer elapses. In this
case, even if the Unit ID of the transmitting transceiver is either the same or different, various functions such as Alert
Tone will not be activated when the Group ID for the Group Call received second time or later is the same as the Group
ID for the Group Call received first time.
Unit ID 1
Receiving
Group ID 1
Various
functions such
as Alert Tone
Auto Reset Timer
A: The transceiver receives a Group Call using the same Group ID from the transceiver (Unit ID 1) having the same Unit
ID before the time configured for Auto Reset Timer elapses, so that various functions such as Alert Tone will not be
activated.
B: Even if the transmitting transceiver has the different Unit ID, the transceiver receives a Group Call using the same
Group ID before the time configured for Auto Reset Timer elapses, so that various functions such as Alert Tone will not
be activated.
C: Even if the transmitting transceiver has the same Unit ID, the transceiver receives a Group Call using the different
Group ID before the time configured for Auto Reset Timer elapses, so that various functions such as Alert Tone will be
activated.
D: The transceiver receives a Group Call using the different Group ID from the transceiver having the different Unit ID
before the time configured for Auto Reset Timer elapses, so that various functions such as Alert Tone will be activated.
E: Even if the transceiver receives a Group Call using the same Group ID, the time configured for Auto Reset Timer has
already elapsed, so that various functions such as Alert Tone will be activated.
Note
If the Alert Tone Restriction from 2nd Call is enabled, various functions such as Alert Tone will not be activated upon the reception of
the second and subsequent calls from the same transceiver even if "Off" is configured for Auto Reset Timer.
Configuration using KPG-111D/ DN
Configuring the Alert Tone Restriction from 2nd Call to be enabled or disabled (
FUNC (K)/Ver 4.00
Unit ID 1
Unit ID 2
Group ID 1
Group ID 1
A
B
Auto Reset
Auto Reset
Timer stops.
Timer stops.
Auto Reset Timer
Auto Reset Timer
Figure 6-3 Alert Tone Restriction from 2nd Call (Group Call)
Unit ID 2
Unit ID 3
Group ID 2
Group ID 3
C
D
Auto Reset
Auto Reset
Timer stops.
Timer stops.
Auto Reset Timer
Auto Reset Timer
See
Unit ID 3
Group ID 3
E
Auto Reset
Timer expires.
Auto Reset Timer
FPRG 8.19.2 General 1 Tab)
CONTENTS
INDEX
98

Advertisement

Table of Contents
loading

Table of Contents