10 ANALOG CONVENTIONAL SYSTEM
10.1 Initiating Voice Communications (Basic Transmission and Reception)
TOT Pre-alert
TOT Pre-alert tone is used to notify a user that a continuous transmission is about to end by the Time-out Timer. The TOT
Pre-alert Tone sounds from the transceiver before the transceiver stops the continuous transmission by the Time-out
Timer.
Example: Time-out Timer: 30 s, TOT Pre-alert: 4 s
Note
If "Off" is configured for TOT Pre-alert, no TOT Pre-alert tone will sound from the transceiver.
TOT Rekey Time
TOT Rekey Time is the amount of time from when the transceiver stops the transmission by the Time-out Timer until
transmission becomes possible again.
Example: Time-out Timer: 30 s, TOT Rekey Time: 20 s
Note
• If "Off" is configured for TOT Rekey Time, the transceiver will immediately be ready to transmit.
• The timer will be reset if the zone or channel is changed while the TOT Rekey Time is counting down.
TOT Reset Time
TOT Reset Time is the time required to initialize and reset the elapsed time for Time-out Timer.
Example 1: Time-out Timer: 30 s, TOT Reset Time: 10 s
FUNC (K)/Ver 4.00
PTT
Press
TOT
Count Start
TOT Pre alert
Alert Start
Time
0 s
Figure 10-2 TOT Pre-alert
PTT
Press
TOT
Count Start
TOT Rekey Time
Count Start
0 s
Time
Figure 10-3 TOT Rekey Time
PTT
Press
Release
TOT
Count Start
TOT Reset Time
TOT Reset Time
Count Start
Time
0 s
10 s
Figure 10-4 TOT Reset Time 1
Transmit End
Transmit
Release
Expire TOT
TOT
Pre-alert
Tone
Alert End
26 s
30 s
Release
Press
Expire TOT
Count Start
TOT Rekey Time
Expire
30 s
50 s
Press
TOT Reset
Count Start
Expire TOT
Expire
20 s
25 s
30 s
55 s