24 TRANSCEIVER DATA PROTECTION WITH PASSWORD
24.2 Password for Reading Configuration Data in a PC (Read Authorization Password)/ 24.3 Password for Writing Configuration Data (Overwrite Password)
2
Press the
Menu ([
If the password matches, a Password Authorization Tone sounds
from the transceiver and the transceiver enters User Mode.
Configuration using KPG-111D/ DN
Configuring the Transceiver Password (
Assigning functions to the PF keys on the transceiver (
24.2
Password for Reading Configuration Data in a PC
(Read Authorization Password)
Read Authorization Password protects the configuration data, such as the operating frequencies, from being read by
unauthorized persons if the transceiver should ever be stolen.
To read the configuration data using KPG-111D/ DN from a transceiver having a Read Authorization Password, the Read
Authorization Password must be entered at a PC. The configuration data in the transceiver cannot be read unless the
correct Password is entered.
Cloning the configuration data would not start unless the correct password is entered when the Read Authorization
Password is configured for the master transceiver. Refer to
Read Authorization Password.
Read Authorization Password can be configured for the transceiver using KPG-111D/ DN. Read Authorization Password
can be configured using any numbers between 0 and 999999 inclusive.
Configuration using KPG-111D/ DN
Configuring the Read Authorization Password (
24.3
Password for Writing Configuration Data
(Overwrite Password)
Overwrite Password protects the configuration data from being overwritten by unauthorized persons if the transceiver
should ever be stolen.
To write data using KPG-111D/ DN to a transceiver for which the Overwrite Password is configured, the password must be
entered at a PC.
Overwrite Password can be configured for the transceiver using KPG-111D/ DN. Overwrite Password can be configured
using any numbers between 0 and 999999 inclusive.
Note
Cloning data from another transceiver cannot be done if the Overwrite Password is configured for the transceiver.
Configuration using KPG-111D/ DN
Configuring the Overwrite Password (
FUNC (K)/Ver 4.00
]) or
[*]
key after entering the password.
See
FPRG 8.10.1 Common Page 1 Tab)
See
FPRG 8.10.1 Common Page 1 Tab)
See
FPRG 8.10.1 Common Page 1 Tab)
See
FPRG 8.12 Key Assignment Window)
Entering or Deleting a Code on page 48