19 SCAN
19.7 Transceiver Behavior during the Scan
Reception during the Scan in a Conventional Group
The transceiver receives according to the configuration for Audio Control.
Behavior after Receiving QT/ DQT/ RAN
If the received QT tone, DQT code, or RAN code on each channel matches the QT tone, DQT code, or RAN code
preconfigured for the receiving transceiver, the transceivers pauses scanning. Dropout Delay Time is activated if the QT
tone, DQT code, or RAN code matching state is reset. After the time configured for Dropout Delay Time elapses, the
transceiver resumes the scan.
Pressing the PTT switch causes the transceiver to transmit on a Revert CH/GID. The transceiver starts counting down the
Dwell Time when the transmission ends, and then resumes scanning after the Dwell Time elapses.
QT/ DQT/ RAN - Optional Signaling AND Transceiver Behavior
If the received QT tone, DQT code, or RAN code matches the QT tone, DQT code, or RAN code preconfigured for the
receiving transceiver, the transceivers pauses scanning. The transceiver does not emit the received audio and then waits
to receive an Optional Signaling (2-tone, DTMF, FleetSync, NXDN ID).
The transceiver resumes scanning after the length of time configured for Dropout Delay Time elapses, if the QT tone, DQT
code or RAN code matching state is reset while waiting to receive the Optional Signaling.
The transceiver emits the received audio and Alert Tone or starts transponding when the received Optional Signaling
matches the Optional Signaling preconfigured for the transceiver while waiting to receive the Optional Signaling. The
transceiver stands by on the channel when the Optional Signaling matches.
QT/ DQT - Optional Signaling OR Transceiver Behavior
If the received QT tone or DQT code matches the QT tone or DQT code preconfigured for the receiving transceiver, the
transceivers pauses scanning. The transceiver emits the received audio and then waits to receive an Optional Signaling.
The transceiver resumes scanning after the amount of time configured for Dropout Delay Time elapses if the QT tone or
DQT code matching state is reset while waiting to receive the Optional Signaling.
If the transceiver pauses scanning when the received Optional Signaling matches the Optional Signaling preconfigured for
the transceiver, the transceiver does not resume scanning even if the Optional Signaling is reset.
Configuration using KPG-111D/ DN
Configuring the Audio Control (
Reception during the Scan in an LTR Trunking System
The transceiver receives as below according to the configuration for Audio Control.
Transceiver Behavior by Group ID
The transceiver pauses scanning when the decoded Group ID matches the Group ID to be scanned. Dropout Delay Time
is activated if the decoded Group ID does not match the Group ID preconfigured for the transceiver. After the time
configured for Dropout Delay Time elapses, the transceiver resumes the scan.
Pressing the PTT switch causes the transceiver to transmit on a Revert CH/GID. The transceiver starts counting down the
Dwell Time when the transmission ends, and then resumes scanning after the Dwell Time elapses.
FUNC (K)/Ver 4.00
See
FPRG 8.2.6 Audio Control (Analog) and 8.2.7 Audio Control (NXDN))