Kenwood NEXEDGE NX-200 Function Reference page 350

Hide thumbs Also See for NEXEDGE NX-200:
Table of Contents

Advertisement

12 FleetSync
12.4 Making a Selective Call
Group ID
Group ID is an ID used to initiate a Group Call in FleetSync.
A Group Call can be initiated by using FleetSync assigning the same Group ID to transceivers that form a group. The call
can be initiated on a smaller scale than a Fleet Call and Supervisor Call. It is usually used within the same fleet.
Call Type
Group Call
A user can respond with a Group Call.
Whether to use Group ID can be configured using KPG-111D/ DN, and also a Group ID can be configured using
KPG-111D/ DN. A maximum of 10 Group IDs can be configured.
Configuration using KPG-111D/ DN
Configuring the Group ID to be enabled or disabled (
Configuring the Group ID (1 to 10) (
Selective Call Alert LED
Selective Call Alert LED can be used to make the LED blink orange when the transceiver receives a call.
A user can notice by the LED that the transceiver is receiving a call.
Note
For NX-200S/ NX-300S, the blinking LED (orange) upon the receipt of a Selective Call indicates the following status of the transceiver.
(a) The transceiver has received a Selective Call (as a status of an incoming call history).
(b) The transceiver can respond to the transmitting transceiver by pressing the PTT switch.
Therefore, if the transceiver receives a Selective Call while the transceiver cannot respond to the transmitting transceiver; for instance,
the transceiver receives an ID inhibited to transmit, the LED blinks orange as the status (a). In this case, the transceiver cannot
respond even if the PTT switch is pressed.
Also, if LED for Auto Reset Timer is disabled and the time configured for Auto Reset Timer has elapsed, the matching status of
Optional Signaling will be reset. At this time, the LED indicating the status (a) continues blinking, so that the transceiver cannot
respond to the transmitting transceiver.
If the LED indicates the status (a), the LED will be turned Off by pressing any key. If the LED indicates the status (b), the LED will be
turned Off by pressing a key to which a specific functions is assigned. (Refer to
Configuration using KPG-111D/ DN
Configuring the Selective Call Alert LED (
FUNC (K)/Ver 4.00
Table 12-7 Group ID Response
ID Configured in ID List
See
See
FPRG 8.16.2 General 1 Tab)
See
FPRG 8.16.2 General 1 Tab)
Response
No ID Configured in ID List
A user can respond with a Group Call. However, a user
may not be able to respond to a call, depending on the
Interfleet configuration and the configuration for Unit
Encode Block.
FPRG 8.16.2 General 1 Tab)
Mode Reset Timer on page
CONTENTS
20.)
INDEX
316

Advertisement

Table of Contents
loading

Table of Contents