Kenwood NEXEDGE NX-200 Function Reference page 386

Hide thumbs Also See for NEXEDGE NX-200:
Table of Contents

Advertisement

13 MDC-1200
13.1 Transmitting/ Receiving a PTT ID
Timing for Sending the PTT ID
The PTT ID is sent with the following timing.
 BOT (Beginning of Transmit)
The PTT ID is added to a signal at the beginning of the transmission.
 EOT (End of Transmit)
The PTT ID is added to a signal at the end of the transmission.
 Both (BOT and EOT)
The PTT ID is added to a signal at the beginning and end of the transmission.
The timing to send the PTT ID can be configured for each channel or GID using KPG-111D/ DN.
Configuratio
n
Off
No PTT ID is sent.
When the PTT switch on the transmitting transceiver is pressed, the ID (Own) in the MDC-1200 format is sent as the
BOT
PTT ID.
When the PTT switch on the transmitting transceiver is released, the ID (Own) in the MDC-1200 format is sent as the
EOT
PTT ID.
Both
At both timing of BOT and EOT, the ID (Own) in the MDC-1200 format is sent as the PTT ID.
Emitting the PTT ID Tone (PTT ID Sidetone)
PTT ID Sidetone is the function to emit a sidetone of the ID (Own) from the speaker while the transceiver is sending an ID
(Own) in the MDC-1200 format.
The calling user can notice the timing to start speaking by the PTT ID Sidetone.
If the calling user starts speaking without noticing that the ID (Own) in the MDC-1200 format is still being sent, the
beginning of the transmitted audio may not be emitted from the speaker of the receiving transceiver. To prevent this
problem, this function needs to be used.
FUNC (K)/Ver 4.00
PTT
Press
Transmit BOT
Figure 13-1 BOT
PTT
Press
Transmit
Figure 13-2 EOT
PTT
Press
BOT
Transmit
Figure 13-3 Both
Table 13-1 Timing to Send the PTT ID
Release
Release
EOT
Release
EOT
Description
CONTENTS
INDEX
352

Advertisement

Table of Contents
loading