8 NXDN CONVENTIONAL SYSTEM
8.10 Sending and Receiving a Short Message (Short Data Call)
Note
If the transceiver receives a Short Message by a Group Call, the ID Name appears according to the configuration for Group Call
Display Type configuration. (Refer to
Configuration using KPG-111D/ DN
Configuring the Message Display Type (
Short Message Stack
Short Message Stack is used to store a Short Message in the stack memory. A maximum of 15 Short Messages can be
stored in the stack memory.
If a message is stored, the "
enters Stack Mode. (Refer to
Note
• A maximum of 15 messages (Status Messages and Short Messages) can be stored in the stack memory.
• This function is unavailable for NX-200S/ NX-300S.
Configuration using KPG-111D/ DN
Configuring the Short Message Stack (
Short Message on Data Zone-CH/GID
Short Message on Data Zone-CH/GID is the function that allows the transceiver to automatically change the channel to the
Data Zone-channel or GID to send a Short Message in an NXDN Conventional system.
The channel in an NXDN Conventional system is automatically changed to the channel configured for a Data Zone-CH/
GID (NXDN) to send the Short Message. The transceiver restores the last Zone-channel or GID when the transmission
ends. Short Message on Data Zone-CH/GID is used to support data communications on a specific dedicated channel.
Note
This function can be only used in an NXDN Conventional system.
Configuration using KPG-111D/ DN
Configuring the Short Message on Data Zone-CH/GID to be enabled or disabled (
Tab)
Configuring the Data Zone-CH/GID (NXDN) (
Sending the Received Short Message from the Communication Port
(Short Message Serial Output)
Short Message Serial Output allows the transceiver to send a Short Message and the Unit ID of the transmitting
transceiver from the transceiver's communication port when the transceiver receives a Short Message.
Using Short Message Serial Output, the dispatcher can monitor received Short Messages in real time.
Note
To use Short Message Serial Output, "Data" or "Data + GPS Data Output" must be assigned to the communication port of the
transceiver.
FUNC (K)/Ver 4.00
Display When the Transceiver Receives a Group Call (Group Call Display Type) on page
FPRG 8.19.2 General 1 Tab)
See
" icon blinks. In this case, a user can read the stored Short Message when the transceiver
3.7 Viewing the Receive History (Stack) on page
See
FPRG 8.10.6 Common Page 4 Tab)
See
38.)
FPRG 8.2.3 Data Zone-CH/GID (NXDN))
See
FPRG 8.19.5 Conventional