8 NXDN CONVENTIONAL SYSTEM
8.9 Sending and Receiving a Status Message (Status Call)
Note
• A maximum of 15 messages (Status Messages and Short Messages) can be stored in the stack memory.
• This function is unavailable for NX-200S/ NX-300S.
Configuration using KPG-111D/ DN
Configuring the Status Message Stack (
Status Message on Data Zone-CH/GID
Status Message on Data Zone-CH/GID is the function that allows the transceiver to automatically change the channel to
the Data Zone-channel or GID to send a Status Message in an NXDN Conventional system.
The channel in an NXDN Conventional system is automatically changed to the channel configured for Data Zone-CH/GID
(NXDN) to send the Status Message. The transceiver restores the last used Zone-channel or GID when the transmission
ends. Status Message on Data Zone-CH/GID can be used to send data on a specific channel.
Note
This function can be only used in an NXDN Conventional system.
Configuration using KPG-111D/ DN
Configuring the Status Message on Data Zone-CH/GID to be enabled or disabled (
Tab)
Configuring the Data Zone-CH/GID (NXDN) (
Sending the Received Status Message from the Communication Port
(Status Message Serial Output)
Status Message Serial Output allows the transceiver to send the Status and the Unit ID of the transmitting transceiver from
the transceiver's communication port when the transceiver receives a Status Message.
Using Status Message Serial Output, the dispatcher can monitor the received Status Message in real time.
Note
"Data" must be assigned to the communication port of the transceiver if using Status Message Serial Output.
Configuration using KPG-111D/ DN
Configuring the Status Message Serial Output to be enabled or disabled (
Power-on Status Message
Power-on Status Message allows the transceiver to send the selected Status Message when the transceiver is turned ON.
Using the Power-on Status Message, the base station can recognize that the transceiver has been turned ON. The
transceiver sends the message to the ID configured for Base ID.
Note
In an NXDN Trunking system, the transceiver ends a transmission without sending the Power-on Status again if the transceiver fails to
send the Power-on Status.
FUNC (K)/Ver 4.00
See
FPRG 8.10.6 Common Page 4 Tab)
FPRG 8.2.3 Data Zone-CH/GID (NXDN))
See
See
FPRG 8.19.5 Conventional
FPRG 8.10.6 Common Page 4 Tab)