9 NXDN TRUNKING SYSTEM
9.1 Initiating Voice Communications (Basic Transmission and Reception)
Configuration using KPG-111D/ DN
Configuring the Selective Call Alert LED (
Over-the-Air Alias
Over-the-Air Alias allows the receiving transceiver to display the ID Name of the transmitting transceiver when receiving a
call even if the ID Name of the transmitting transceiver is not configured for the receiving transceiver.
Using this function, Unit ID Name of the added unit does not need to be configured such as when a unit is added to the
system in service.
The transmitting transceiver sends Unit ID Name when making voice calls. If the receiving transceiver receives a call such
as an Individual Call, the Unit ID Name stored in the reception frame will appear on the main display.
Note
The received Unit ID Name appears after displaying differently from the received Unit ID Name in the following cases.
• The Unit ID of the transmitting transceiver is not configured in the Unit ID List.
• The Unit ID of the transmitting transceiver is not stored as Caller ID.
• The received Unit ID Name is different from the ID configured in the Unit ID List or the ID Name stored in the transceiver.
Configuration using KPG-111D/ DN
Configuring the Over-the-Air Alias to be enabled or disabled (
Receiving a High-priority Call (Priority Monitor ID)
In an NXDN Trunking system, a Priority Monitor ID is the ID that the transceiver preferentially receives when the
transceiver is making voice calls using Group Call on a traffic channel. When the transceiver receives a Priority Monitor ID,
the transceiver will change the mode to that of the call.
4 Priority Monitor IDs can be configured in a zone using KPG-111D/ DN.
Transceiver Behavior
1
The transceiver receives a Priority Monitor ID while the transceiver is making voice calls using Group
Call on a traffic channel.
Alert Tone (Conference Group Call or Broadcast Group Call)
sounds from the transceiver and then the transceiver will start
communicating using the Priority Monitor ID.
• If the transceiver receives the Priority Monitor ID 1:
FUNC (K)/Ver 4.00
See
FPRG 8.19.4 Trunking Tab and 8.19.5 Conventional Tab)
See
FPRG 8.19.2 General 1 Tab)