13 MDC-1200

13.2 Transceiver Behavior in Emergency Mode

13.2
Transceiver Behavior in Emergency Mode
Emergency Mode can be used to transmit and receive with the transceiver in emergencies. In such emergency situations,
a user can immediately contact the base station by using this function. The transceiver can notify the base station of an
occurrence of an emergency situation by sending an Emergency Alarm Request message or an Emergency ID in the
MDC-1200 format.
Emergency Alarm
The transceiver can notify the base station of an occurrence of an emergency situation by sending an Emergency Alarm
Request message. (Refer to
Emergency ID (MDC-1200)
The transceiver can notify the base station of an occurrence of an emergency situation by sending an Emergency ID in the
MDC-1200 format when the transceiver starts transmitting in Emergency Mode. (Refer to

Placing the Transceiver in Emergency Mode

The transceiver enters Emergency Mode according to the configuration for Emergency Alarm by pressing and holding the
Emergency key longer than the amount of time configured for Emergency-key Delay Time. (Refer to
(MDC-1200 Only) on page
Transceiver Behavior When the Transceiver Receives an Emergency ID
(Emergency Response)
Emergency Response is the function that is used to notify a user of that the transceiver has received either an Emergency
Alarm Request message or an Emergency ID in the MDC-1200 format.
When the transceiver receives an Emergency Alarm Request message or an Emergency ID in the MDC-1200 format, the
receiving transceiver notifies a user of that an Emergency Call is received according to the configuration for Emergency
Response, for example, by displaying the received ID or ID Name in the MDC-1200 format on the LCD or emitting an Alert
Tone.
Following is the transceiver behavior while each function of Emergency Response is enabled.
LCD
"EMERGENCY" and the received ID (or ID Name or ID List number) appears on the main display alternately at 1-sec
intervals if the transceiver receives an Emergency Alarm Request message or an Emergency ID in the MDC-1200 format.
If no received ID is configured for ID List in MDC-1200, the ID will appear.
If the received ID is configured for ID List in MDC-1200, the corresponding ID Name will appear. However, if the received
ID is configured for ID List in MDC-1200 but no ID Name is configured, ID List number will appear.
FUNC (K)/Ver 4.00
Emergency Alarm (MDC-1200 Only) on page
394.)
394.)
Emergency ID on page
Emergency Alarm
CONTENTS
402.)
INDEX
355