19 SCAN
19.2 Scanning in One Zone (Single Scan)
Auto Scan
 Group Scan
If a zone is selected in an LTR Trunking system, the transceiver automatically scans the target Group IDs in the
selected zone.
Whether the transceiver automatically scans can be configured using KPG-111D/ DN. (Refer to
Target Group IDs for Scanning Automatically (Group Scan) (LTR Trunking System Only) on page
19.2
Scanning in One Zone (Single Scan)
The transceiver scans using Single Scan all the channels or GID to be scanned in the zone where the transceiver starts
scanning.
Channels or GIDs to be scanned are configured as the target channels or GIDs for scanning using the Scan Delete/Add
key or KPG-111D/ DN.
If a zone in a Conventional Group or LTR Trunking system is selected, Priority Channel is scanned even if no Priority
Channel is configured in the zone to be scanned.
To use Single Scan, "Single" must be configured by using KPG-111D/ DN for Scan Type in a Conventional Group or an
LTR Trunking system, and "Single" must be configured for Scan Type (NXDN Trunking) in an NXDN Trunking system.
Note
• If Selected CH/GID Scan is enabled, the selected channel or GID can be scanned even if the channel or GID is excluded from the
target channels or GIDs for scanning. (Refer to
• A Group ID for which "ALL" is configured or a Group ID which is configured for Priority Monitor ID is always scanned regardless of the
configuration for Delete or Add in an NXDN Trunking system.
• If using Single Scan, the transceiver pauses scanning when the zone is changed to a zone which is not configured using the Selector
for which "Zone Select" is configured. (NX-200/ NX-200S/ NX-300/ NX-300S only)
• During a Single Scan in an NXDN Trunking system, only the Priority Monitor ID configured for the selected zone is used as a Priority
Monitor ID.
Operating the Transceiver
1
Press the
Scan
key.
The transceiver starts scanning.
"SCAN" appears on the main display and the "
For NX-200S/ NX-300S, the LED blinks green.
Note
If a channel or GID is fixed and the transceiver cannot resume
scanning, such as when the transceiver is migrating to the
Home Channel or GID, etc., the "
Stop Tone continues to sound from the transceiver.
FUNC (K)/Ver 4.00
Selected CH/GID Scan on page
" icon appears.
" icon blinks and a Scan
19.6 Scanning the