9 NXDN TRUNKING SYSTEM
9.19 Transceiver Behavior in the Case that the Site Fails to Connect to the Network (Network Failure)
Note
• While the system is in the Failsoft state, functions on a control channel, such as location registration, will not be available.
• If the transceiver acquires a control channel in Failsoft Mode, the transceiver exits Failsoft Mode and then starts location registration.
The transceiver also starts location registration if the transceiver acquires a control channel in the site where the location of the
transceiver has already been registered or the transceiver acquires a control channel in another site.
• If the transceiver is unable to acquire a Failsoft Channel, the transceiver will not enter Failsoft Mode.
• The transceiver cannot migrate from the Failsoft Channel to another channel because the transceiver is unable to acquire a control
channel, even if the transceiver migrates to another NXDN Trunking Zone while the transceiver is in Failsoft Mode.
• The transceiver temporarily pauses a scan if the transceiver enters Failsoft Mode during the scan. The scanning remains paused
temporarily even if the transceiver exits Failsoft Mode.
• For NX-200S/ NX-300S, the status of the transceiver can be confirmed by the LED.
Configuration using KPG-111D/ DN
Configuring the Failsoft Channel (
Configuring the Search Interval Time (
9.19
Transceiver Behavior in the Case that the Site Fails to
Connect to the Network (Network Failure)
Network Failure is the function to provide a communication capability as a single site within a site if the site fails to connect
to the network in a multi-site system due to a system failure. Use of this function allows the transceiver to communicate
within the site even if the system is in the state of Network Failure.
Upon the receipt of the broadcast message notifying that the system is in the state of Network Failure, the transceiver
enters Network Failure Mode. If Network Failure Indicator is enabled, "NETWORK FAIL" and a GID name alternately
appear on the main display of the transceiver at 1-sec intervals while the transceiver is operated in Network Failure Mode.
At 1 second
intervals
NX-200/ NX-210/ NX-300/ NX-410/ NX-411
Also, If Network Failure Tone is enabled, a Network Failure Tone A sounds at 5-sec intervals from the transceiver while the
transceiver is operated in Network Failure Mode, and a Network Failure Tone B sounds from the transceiver when the
transceiver exits Network Failure Mode.
Note
• The transceiver cannot transmit by Site Roaming while the system is in a state of Network Failure.
• Even if the transceiver is operating in Network Failure Mode, the Background Hunt will operate as normal.
• Pressing any key on the transceiver stops the Network Failure Tone A from sounding.
Configuration using KPG-111D/ DN
Configuring the Network Failure Indicator (
Configuring the Network Failure Tone (
FUNC (K)/Ver 4.00
See
FPRG 8.8.16 Failsoft Channel Window)
See
FPRG 8.25.12 Search Interval Time)
See
FPRG 8.25.10 Network Failure Indicator)
FPRG 8.25.11 Network Failure Tone)
See
At 1 second
intervals
Mobile