3 Maintenance
3.3.14 Inspecting the signal lamp (option)
3.3.14 Inspecting the signal lamp (option)
Location of signal lamp
The signal lamp is located as shown in this figure.
Required tools and equipment
Equipment
Signal lamp kit
Standard toolkit
Inspecting, signal lamp
Use this procedure to inspect the function of the signal lamp.
1
2
3
138
Action
Inspect that signal lamp is lit when motors are put in
operation ("MOTORS ON").
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot working area.
If the lamp is not lit, trace the fault by:
•
inspecting whether the signal lamp is broken.
If so, replace it.
•
inspecting cable connections.
•
inspecting the cabling. Replace the cabling if
a fault is detected.