4 Repair
4.5.3 Replacing the axis-6 unit
Continued
9
10
11
12
13
Continues on next page
340
Action
Secure the axis-6 motor cable to the cable
fixing bracket with a cable tie.
Note
The position of axis-4 depends on the on-
going procedure.
Remove all residues of old sealant and
other contamination from the contact sur-
faces of the wrist cover.
Make sure the contact surface of the wrist
cover is undamaged.
Apply flange sealant on the wrist cover
flange.
Place the cable harness so it will not be
damaged when fitting the cover.
© Copyright 2015-2018 ABB. All rights reserved.
Note
xx1500003101
xx1500002331
xx1600000046
Loctite 574
Product manual - IRB 8700