ABB IRB 8700 Series Product Manual page 172

Hide thumbs Also See for IRB 8700 Series:
Table of Contents

Advertisement

3 Maintenance
3.4.7 Changing oil, axis-6 gearbox
Continued
9
10
11
12
172
Action
Required oil level is when the oil level is
visible just below the lower edge of the in-
spection hole, with axis-5 approximately
jogged +82° from the starting position.
Add or drain oil, if required.
Refit the oil plug.
DANGER
Make sure all safety requirements are met
when performing the first test run. These
are further detailed in the section
run may cause injury or damage on
page
27.
© Copyright 2015-2018 ABB. All rights reserved.
Note
xx1700001292
Type of oil and total amount is detailed in
Technical reference manual - Lubrication
in gearboxes.
Further information about how to drain or
fill with oil is found in section
axis-6 gearbox on page
Tightening torque: 24 Nm
First test
Changing oil,
168.
Product manual - IRB 8700
3HAC052853-001 Revision: F