Product manual - IRB 8700
3HAC052853-001 Revision: F
Action
Remove the attachment screw with washer
that secure the rod shaft.
Remove the protection plugs 4 + 4 (two on
either side of the upper arm wings).
Note
Keep the protection plugs. They shall be
refitted when the work is done.
Fit 2 + 2 M10x80 screws in the holes and
adjust the screws against the parallel rod
from both sides.
Remove the protection plug.
Note
Keep the protection plug. It shall be refitted
when the work is done.
© Copyright 2015-2018 ABB. All rights reserved.
4.6.3 Replacing the parallel rod
Note
xx1400002600
xx1500001961
This is done to prevent the upper arm
wings from pinching when pressing the
shaft and thereby making it more difficult
to press the shaft in or out.
Attachment screws: M10x80 (4 pcs)
xx1500002300
xx1500001967