ABB IRB 8700 Series Product Manual page 233

Hide thumbs Also See for IRB 8700 Series:
Table of Contents

Advertisement

8
9
10
11
12
13
Product manual - IRB 8700
3HAC052853-001 Revision: F
Action
Refit the motor cover.
Secure the axis-6 motor cable to the cable
fixing bracket with a cable tie.
Note
The position of axis-4 depends on the on-
going procedure.
Remove all residues of old sealant and
other contamination from the contact sur-
faces of the wrist cover.
Make sure the contact surface of the wrist
cover is undamaged.
Apply flange sealant on the wrist cover
flange.
Place the cable harness so it will not be
damaged when fitting the cover.
© Copyright 2015-2018 ABB. All rights reserved.
4.4.2 Refitting the cable harness
Note
Attachment screws: M5x20 (5 pcs)
xx1200001080
xx1500003101
xx1500002331
xx1600000046
Loctite 574
Continues on next page
4 Repair
Continued
233

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Irb 8700-550/4.20Irb 8700-800/3.50Irc5

Table of Contents