Securing the axis-6 motor
1
2
3
4
Product manual - IRB 8700
3HAC052853-001 Revision: F
Action
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot
working area.
To release the brakes, connect the 24 VDC
power supply.
Connect to connector R2.MP6:
pin 2 = 24V
pin 5 = 0V
Make sure that there is enough grease on
the splines, before fitting.
If not, apply 1 gram of grease.
CAUTION
Whenever parting/mating motor pinion and
hub, the splines may be damaged if excess-
ive force is used.
© Copyright 2015-2018 ABB. All rights reserved.
4.7.5 Replacing the axis-6 motor
Note
Grease: Castrol Molub. Alloy 777-1 NG
xx1500002346